Activity
From 06/01/2018 to 06/30/2018
06/25/2018
- 03:02 PM Analyzing #199: Determination of positions of silicone detectors
The orientation thin detector in the thick detector with taking into account possible errors. The center points of th...
06/24/2018
- 02:13 AM Analyzing #186: Number of 3He coincidences with 3H
We worked with run14 of exposition on 6He beam saved in lmd files:
XXX
Scripts for data treatment are availab...
06/19/2018
- 05:02 PM Analyzing #198 (Закрыта): Determination of thickness inhomogeneity of thin silicon detector
06/18/2018
- 06:20 PM Analyzing #186: Number of 3He coincidences with 3H
Analysis of data with beryllium beam gives interesting results. Data
mbsdaq@nra161:/LynxOS/mbsusr/mbsdaq/mbsru...
06/16/2018
- 03:50 AM Analyzing #186: Number of 3He coincidences with 3H
We compared dE-E identification plots obtained from experimental data (run 14) with data used for calibrations giving...
06/15/2018
- 02:13 AM Analyzing #183: Express analysis of experimental data
Raw data may be converted into ROOT format in following way:
Go4 library must be available. One of the well w...
- 11:02 AM Analyzing #195 (Закрыта): First estimate of inhomogeneity of thin Si detector
Phenomena was studied deeply in issue 198.
06/14/2018
- 02:26 PM Analyzing #198: Determination of thickness inhomogeneity of thin silicon detector
the same macros was used for determination of thickness of 20um det, but this time each SQY_L strips was separated in...
06/07/2018
- 02:11 PM Analyzing #198: Determination of thickness inhomogeneity of thin silicon detector
I have contacted the Micron Semiconductors. There is no input control of the thickness uniformity. They rely only upo...
- 01:58 PM Analyzing #198: Determination of thickness inhomogeneity of thin silicon detector
files 159.93.80.161:/LynxOS/mbsusr/mbsdaq/mbsrun/exp201804/data/calib/si_after/si-1_si-20_35cm_0deg_new1_*.lmd were p...
- 11:48 AM Developing #187: Калибрация 1 мм кремневого детектора
For data obtained in measurements with SQL, by irradiating it from 35 cm with 90 and 45 angle. In this measureme...
06/06/2018
- 02:50 PM Developing #187: Калибрация 1 мм кремневого детектора
We should compare the count rate in peaks with what is expected. Nominal activity is 3*10^4 Bq. For a pixel size of...
- 12:08 PM Analyzing #198: Determination of thickness inhomogeneity of thin silicon detector
In data 159.93.80.161:/LynxOS/mbsusr/mbsdaq/mbsrun/exp201804/data/calib/si_after/si-1_si-20_35cm_0deg_new1_*.lmd ther...
06/05/2018
- 06:20 PM Analyzing #199: Determination of positions of silicone detectors
The script for determine position of detectors:
- 06:00 PM Analyzing #199: Determination of positions of silicone detectors
The active area of thin detector is 50mm:50mm and there are 16 stripes for axis X (from left to right SQY_R[0]->SQY_...
06/04/2018
- 12:36 PM Developing #184: Калибрация тонково кремневого детектора
From the data obtained in meauserements described in task 197 dead layer was calculated. calculations was made https:...
- 11:55 AM Analyzing #198: Determination of thickness inhomogeneity of thin silicon detector
In order to analyse the properties last strips (12-15) data from measurements, where alpha source was moved to the le...
06/01/2018
- 01:19 PM Analyzing #199: Determination of positions of silicone detectors
We used data file si-1_si-20_35cm_0deg_new1_0003.lmd We took into account that center of the thick 1mm detector is ...
- 10:37 AM Developing #197: Measurement of thickness of thin silicon detector
Several measurements were carried out. In all of them two detectors were used. 20 mcm (discription see in file 7306 r...
Also available in: Atom