04/07/2020
- 07:59 AM EXP2003: Express analysis Analyzing #452: Beam projection
Under the condition that at least one wire was fired in each MWPC plane, we observed time distribution for individual...
04/05/2020
- 12:33 AM EXP2003: Express analysis Analyzing #454: ID plot for F6 detector
To construct an identification plot from the F6 detector, a non-calibrated amplitude in ADC channels from only one PM...
04/04/2020
- 01:43 AM EXP2003: Express analysis Analyzing #452: Beam projection
Target plane
We worked with the 8He beam particles only (selected by ToF system). We assumed the numbering of MWPC...
- 12:02 AM EXP2003: Express analysis Analyzing #457: Attempt for relative calibration of side telescope
We checked if the double dE-E line on ID plot reported in task 453 was not caused by issues related to calibration. W...
04/02/2020
- 04:36 PM EXP2003: Express analysis Analyzing #453: ID plot for side telescope
The first layer of side telescope was calibrated using parameters provided in task 445. The second layer was not cali...
- 10:54 AM EXP2003: Express analysis Analyzing #455: Estimation of the beam integral
For the beam integral calculation following selections were used:
8He selection by dE-ToF
center of the targe...
03/31/2020
- 02:44 AM EXP2003: Express analysis Analyzing #457 (Открыта): Attempt for relative calibration of side telescope
Side silicon telescope intended for registration of 3He was not fully calibrated before the beginning of the beam ses...
- 02:40 AM EXP2003: Express analysis Analyzing #456 (Открыта): Neutron detector data
Provide current data from the neutron detector.
In separate comments
describe the calibration of the detecto...
- 02:35 AM EXP2003: Express analysis Analyzing #455 (Открыта): Estimation of the beam integral
Estimate the 8He beam integral for a particular beamtime period.
Try to estimate the 8He beam integral under a re...
- 02:30 AM EXP2003: Express analysis Analyzing #454 (Открыта): ID plot for F6 detector
Provide the time-amplitude identification plot for a detector at F6. A group Z=1 should be separated from group Z>1. ...
- 02:25 AM EXP2003: Express analysis Analyzing #453 (Открыта): ID plot for side telescope
Provide a standard identification dE-E plot for side telescope.
Estimate the number of registered
3He;
6Li...- 02:22 AM EXP2003: Express analysis Analyzing #452 (Открыта): Beam projection
Provide a beam projection in
MWPC1 plane
MWPC2 plane
target plane